10KW 48V Off-Grid Solar Storage Inverter 110V/240V Pure Sine Wave with Built-in 2 MPPT Solar Controllers

TYCORUN’s 48V solar inverters have strong safety, lightning protection, and are suitable for extreme environments. The product has complete power protection measures and is equipped with a built-in MPPT photovoltaic charger for rational and efficient energy utilization, ensuring continuous power supply.

  • Wide PV input voltage range 60Vdc-500Vdc
  • Compatible with lithium, lead-acid and GEL batteries
  • Complete protection with a long service life
  • Industrial grade design supporting long-term high load operation
  • Stable performance, in compliance with international certification standards
Two Mppt, max. 22A string current, PV input 12kw

Equipped with two Maximum Power Point Trackers (MPPTs) that support a maximum string current of 22A and a maximum solar input of 10kW. This enhances the efficiency of solar energy capture and ensures optimal performance from solar arrays.

Dual AC outputs for smart load management

Equipped with dual AC outputs, allowing for intelligent load management. This feature ensures efficient power distribution between different loads, optimizing energy usage and enhancing system performance.

48V 10kW Off-Grid Solar Inverter

Supports a wide PV input voltage range from 30Vdc to 500Vdc, accommodating various solar panel configurations. This flexibility enables users to design systems that best meet their specific energy needs and conditions.

ModelSF 8000SF 10000User-
Settable
Nominal Battery Voltage48Vdc48Vdc 
Battery TypeLithium LiFePO4/Lead-Acid/Flood /User Defined✓
AC INPUT
Nominal AC Input Voltage/Waveform230Vac/Sinusoidal (Utility or Generator) 
AC Input Range90~280Vac (Appliances);170Vac~280Vac (UPS)✓
Nominal Input Frequency50/60Hz (Auto Detection)✓
AC Input Frequency Range40~65±1Hz; (>42 or <63±1Hz Comeback) 
Max. Bypass Current50Amp 
Output Short Circuit ProtectionCircuit Breaker 
Transfer Time15ms Typical (UPS); 25ms Typical (Appliances) 
AC CHARGER
Charging Algorithm3-Step 
Max. AC Charging Current120Amp (@VI/P=230Vac)✓
Bulk Charging Voltage56.4Vdc (AGM/Gel Battery);58.4Vdc (Flooded Battery)✓
Floating Charging Voltage54Vdc✓
Max. Hybrid Charging Current (Solar & Utility)150Amp✓
PV INPUT
Num. of Independent MPPT Tracker2 
MPPT Input Current2*22Amp 
Max. PV Array Power12000W12000W 
Max. Solar Charge Current150Amp✓
PV Array MPPT Voltage Range60~450Vdc 
Max. PV Array Open Circuit Voltage500Vdc 
MPPT Tracking Efficiency99.9% 
INVERTER OUTPUT
Num. of Output Ports (Main & Second Output)2 
Rated Output Power of Main/Second Output*【1】8000W/8000W10000W/10000W 
Max. Output Current of Main/Second Output34.8A/34.8A43.5A/43.5A 
Surge Capacity16000VA/16000W for 5 Seconds20000VA/20000W for 5 Seconds 
Output Voltage WaveformPure Sine Wave 
Overload Protection5s@150% Load; 10min@110% Load;10s@125% Load; 
Output Voltage220/230/240 Vac ± 5% 
Output Frequency50Hz/60Hz ±1 Hz 
Peak Efficiency94% 
Low Voltage Cut-off Voltage42Vdc✓
High Voltage Cut-off Voltage63Vdc 
Cold Start Voltage (When Only Connect with Battery)46Vdc 
No Load Power Consumption<70W@48Vdc 
Parallel CapacityN/A 
GENERAL
Operating Temperature Range-10°C to 50°C 
Storage Temperature-15°C~60°C 
Humidity5% to 95% Relative Humidity (Non-Condensing) 
Altitude<2000m 
Noise≤60dB 
Protection DegreeIP21,Indoor OnIy 
Cooling MethodIntelligent Fan 
Dimensions(W*H*D)500*390*138 mm500*390*138 mm 
Weight18 KG18 KG 
Warranty2 Years 
COMMUNICATION
Embedded InterfaceRS232*1/RS485*1/Dry Connection 
Work with Bluetooth Monitoring Dongle (Optional)YES, by RS232 
Work with Lithium Battery BMSYES, by RS485 
CERTIFICATION
Certification/StandardCE(IEC61000,IEC62109) ; IEC61683,IEC60068 ; RoHS 

The 48V system has lower current and reduced transmission loss, TYCORUN making it suitable for higher power scenarios. A 1000W inverter belongs to a large-scale off grid system, which can cover the power supply needs of commercial buildings and small industrial parks.

TYCORUN off-grid solar inverters are equipped with intelligent monitoring systems that can view the operating status in real time and adjust configurations. Compatible with multiple load types, and supports overload up to 150% of rated power, automatically recovering within seconds.

Adopting modular design for easy transportation and on-site installation. Provide detailed installation manuals and video guidance to ensure rapid deployment.

Other Products from TYCORUN | Leading Inverter Supplier for Solar Power Solutions

Additional Resources About Solar Inverters

How to Convert Amp Hours to Watt Hours (Ah to Wh Calculator and Chart)

How to Convert Amp Hours to Watt Hours (Ah to Wh Calculator and Chart)

Convert amp hours to watt hours with one formula: Wh = Ah × V. This guide gives you a calculator, lookup charts from 12V to ...
Lithium Battery for RV Off-Grid Sizing and Cold Charging

Lithium Battery for RV: Off-Grid Sizing and Cold Charging

Planning an off-grid RV trip or camping in winter? Find out how much battery capacity you need, how to match it to your appliances, and ...
Ganfeng Begins 588Ah Storage Cell Ramp; 648Ah Planned for 2027

Ganfeng Ramps 588Ah Storage Cells, 648Ah Due 2027

Ganfeng LiEnergy has moved its 588Ah storage cell line into production ramp and scheduled a 648Ah cell for 2027. This article converts the new formats ...