Two batteries sit on the same shelf, both stamped 100Ah. One runs a pump for eight hours. The other manages four. Nothing on either label explains the gap, and the number that would explain it is not the one printed in large type.
That number is watt hours. This guide covers what a watt hour actually measures, the formulas that produce it, why the watt hours on a label are not the watt hours you can use, and how to measure the inputs yourself without damaging your meter.
- Watt hours measure energy. Watts measure power. The two differ by time.
- Amp hours measure charge and leave voltage out, so they cannot be compared across different pack voltages.
- The core formulas are Wh = Ah × V and Wh = W × h.
- Usable watt hours run well below nameplate because of depth of discharge, conversion losses, temperature and discharge rate.
What a Watt-Hour Actually Measures
Power and energy get used interchangeably in product copy, and that confusion is where most sizing errors start. Power, in watts, is the rate at which energy moves. Energy, in watt hours, is how much moved in total.
A 100W lamp switched on for one hour consumes 100Wh. Leave it on for three hours and it consumes 300Wh. The power never changed, only the time did. Watt hours are simply watts multiplied by hours.
To calibrate the scale:
- A 4,000mAh phone battery at 3.7V holds roughly 15Wh, which is why mAh on its own says little without a voltage.
- A laptop pack runs 50 to 90Wh.
- A 48V 20Ah e-bike pack holds 960Wh, just under 1kWh.
- A home storage unit is usually quoted in kWh, commonly from 5 to 15kWh for a typical house.
Once you have that ladder in your head, most spec sheets stop being abstract.
Why Amp-Hours Cannot Be Compared Across Voltages
Amp hours measure charge, not energy. Charge is current multiplied by time, so a 100Ah battery can deliver 100A for one hour, or 1A for a hundred hours. That tells you how long it lasts at a given current, but nothing about how much work it can do, because voltage is left out. The full definition is in our guide to what Ah means on a battery label.
Voltage is the missing half. Multiply charge by voltage and you get energy:
Wh = Ah × V
The same amp hour number therefore produces very different energy at different voltages.
| Emballage | Ah | Tension nominale | Watt hours |
|---|---|---|---|
| 12V 100Ah | 100 | 12V | 1,200Wh |
| 24V 100Ah | 100 | 24V | 2,400Wh |
| 48V 100Ah | 100 | 48V | 4,800Wh |
| 48V 30Ah | 30 | 48V | 1,440Wh |
Read the first and last rows together. A 48V 30Ah pack carries more energy than a 12V 100Ah pack, 1,440Wh against 1,200Wh, even though its amp hour rating is less than a third of the other. Compare them on Ah alone and you pick the wrong battery. Compare them on watt hours and the answer is immediate.
This also solves the puzzle from the start of this guide. If the two 100Ah batteries are a 12.8V lithium pack and a 25.6V lithium pack, they hold 1,280Wh and 2,560Wh. A pump drawing 320W runs for about four hours on the first and about eight hours on the second, before any losses. The Ah label was identical, but the energy was not.
One correction that matters if you work with lithium iron phosphate (LiFePO4): the nominal voltage of a “12V” pack is 12.8V, not 12V. A 100Ah LiFePO4 pack is 1,280Wh, not 1,200Wh. The same applies at 25.6V for “24V” packs and 51.2V for “48V” packs.
The Formulas, and When to Use Each
Three formulas cover almost everything, and a fourth converts the result to billing units.
| You know | Formula | Typical situation |
|---|---|---|
| Power and time | Wh = W × h | The appliance label gives watts and you know the hours |
| Voltage, current, time | Wh = V × A × h | Measuring a DC circuit with a meter |
| Amp hours and voltage | Wh = Ah × V | Sizing from a battery label |
| Watt hours to kilowatt hours | kWh = Wh ÷ 1000 | Reading a utility bill or a spec sheet |
The first two are the same equation. Power equals voltage times current, so V × A × h becomes W × h. Use whichever matches the numbers you already have. If you would rather not do the arithmetic by hand, the amp hours to watt hours converter takes voltage and capacity and returns energy directly.
Worked Examples
Example 1: A DC Load
A 12V device drawing 5A for 3 hours.
Wh = 12 × 5 × 3 = 180Wh
Example 2: A 12.8V 200Ah Lithium Pack
Nameplate energy: 12.8 × 200 = 2,560Wh, or 2.56kWh.
Now the part many guides skip. Run a 3,000W load through an inverter and you do not get 2,560Wh of usable output. Assume 90% depth of discharge and 92% inverter efficiency:
2,560 × 0.90 × 0.92 = about 2,120Wh
2,120 ÷ 3,000 = 0.71 hours, or about 42 minutes.
A pack sold as 2.56kWh delivers about 42 minutes at 3kW. That is not a defect, it is what the chemistry and conversion losses allow. Sizing without this step is how systems end up shutting down early in the field. The 90% and 92% figures are planning assumptions, so use the depth of discharge your battery maker recommends and your inverter’s rated efficiency.
Example 3: The Classic Runtime Error
A 1,000Wh battery powering a 100W load. Nameplate maths says ten hours. Apply the same derating:
1,000 × 0.90 × 0.92 = 828Wh
828 ÷ 100 = about 8.3 hours
Roughly a sixth of the runtime disappears before the battery has aged at all. If you also allow for 5% capacity fade after a few years of use, the figure drops to about 7.9 hours.
Example 4: Sizing Backwards From a Bill
A household uses 12kWh a day and wants to shift that load onto a battery. The bank has to deliver 12kWh usable, not 12kWh nameplate.
At 90% depth of discharge: 12 ÷ 0.90 = 13.3kWh of nameplate capacity.
Add 92% inverter efficiency on the discharge path and the figure rises to about 14.5kWh. A 15kWh bank is a sensible answer. A 12kWh bank would run short on the days with the least sunshine and the highest demand, which is usually winter, and those are the days the system matters most.
Nameplate Watt-Hours Are Not Usable Watt-Hours
Several losses sit between the label and the socket. Roughly in descending order of size:
Depth of discharge. Lead acid batteries are commonly kept above about 50% charge to protect cycle life, while LiFePO4 packs typically allow 80 to 90% or more. This is usually the biggest gap between rated and usable energy, and it is a design choice rather than a defect.
Conversion losses. A good pure sine inverter returns around 90 to 95%. DC to DC converters vary more widely. Every stage between the battery and the load takes a cut.
Température. Usable capacity falls in the cold, and charging a lithium pack below 0°C is generally not recommended unless it has internal heating. A pack rated at 25°C is not the same pack in a cold store.
Discharge rate. Pulling high current from a small pack delivers less than its rated amp hours. The effect is pronounced on lead acid and milder on lithium, but it does not vanish.
Charging losses. Energy also leaves the pack less efficiently than it enters. Round trip efficiency for a LiFePO4 pack with a good BMS is typically around 92 to 95%, and for lead acid it is typically lower, often 75 to 85%. If a site needs 10kWh delivered per day and round trip efficiency is 93%, the solar array and charge path have to supply about 10.8kWh.
Here is the whole chain on one pack.
| Scène | L'énergie | Facteur |
|---|---|---|
| Nameplate, 12.8V 200Ah | 2,560Wh | 1.00 |
| After 90% depth of discharge | 2,304Wh | 0.90 |
| After 92% inverter efficiency | about 2,120Wh | 0.92 |
| After 5% capacity fade, year three | about 2,014Wh | 0.95 |
Two thousand watt hours, not two thousand five hundred and sixty. Both numbers are honest, but only one tells you what the system will do on a cold night in February.
If you are comparing packs rather than sizing a load, the nameplate figure is fine as long as you compare like with like. The difference between rated, nominal and tested capacity is covered in our guide to how battery capacity is measured.
How to Measure the Inputs Without Damaging Your Meter
Voltage is the safe one. Set a multimeter to DC volts, put the red lead on positive and the black lead on negative, and read the number. Resting voltage gives only a rough idea of charge level, and on LiFePO4 the voltage curve is so flat that it is a poor fuel gauge. For an accurate state of charge, use the BMS readout or a battery monitor.
Current is where people destroy equipment. A 12V 100Ah LiFePO4 pack can deliver several hundred amps into a short circuit. A multimeter on its 10A range wired in series with that pack can blow its fuse at best and damage its internal shunt at worst. The common advice to use the 10A range was written for small electronics, not for large packs. Use one of these instead:
- A clamp meter, which reads current without breaking the circuit.
- A shunt based battery monitor, which logs amp hours and watt hours continuously.
- The readout from a smart lithium-ion battery BMS, since many lithium packs report energy in and out.
Time is easy once the other two are logged. If your BMS exports a log, you can skip the manual measurement and read it directly.
For small devices, a plug in energy meter between the socket and the appliance gives you watt hours directly. It is usually more accurate than a hand calculation from nameplate ratings, because it measures what the device actually draws rather than what the label claims.
Where Watt-Hours Change the Decision
Spec sheets use watt hours in three different ways, and mixing them up is a common source of disappointment.
Cell level watt hours are the raw energy of the cells before packaging, BMS and thermal management. This is the largest number and the least useful.
System level watt hours are what the finished pack holds at its terminals. This is the number a reputable manufacturer quotes, and it is the one to compare.
Output watt hours appear on portable power stations and refer to what comes out of the AC socket, after the inverter. A unit advertised as 1,000Wh may deliver noticeably less at the outlet, for example 850 to 900Wh. Neither figure is dishonest, but they are not the same figure.
When two products differ by 10% on watt hours, check which level each is quoted at before you assume one is better. For anything you plan to run on a schedule, ask for the system level watt hours and the depth of discharge the manufacturer recommends. Those two numbers, more than the headline capacity, determine what the pack will actually deliver.
Where Watt-Hours Change the Decision
Five situations where the number earns its keep.
Comparing packs across voltages. This is the only fair basis. A 48V 30Ah pack and a 12V 100Ah pack are not comparable in Ah, but they are comparable in Wh.
Sizing runtime. Divide the load in watts into the usable watt hours to get hours. Do the derating first, not after the customer complains.
Sizing solar and storage. Daily consumption in Wh sets the array and the bank. A household using 3,000Wh a day needs at least 3,000Wh of usable storage, which at 90% depth of discharge means a bank of about 3,300Wh before you add days of autonomy.
Sizing against weight or volume. For a vehicle or a portable unit, watt hours per kilogram and per litre matter as much as the total. Two packs with the same nameplate energy can differ noticeably in mass depending on chemistry and design, and on a two wheeler that difference shows up as range.
Reading a bill. Utilities charge in kWh. Wh divided by 1,000 is the bridge between your pack and your invoice, and it is the way to compare a battery’s cost per delivered kWh against grid power.
Six Mistakes That Survive Most Guides
- Treating amp hours as energy. Two packs with identical Ah and different voltage hold different energy.
- Using 12V for a LiFePO4 pack. It is 12.8V nominal. The error is small per unit but compounds across a bank.
- Forgetting depth of discharge. A 100Ah lead acid battery does not give you 100Ah of usable capacity, and a LiFePO4 pack does not give you its full nameplate either.
- Comparing nameplate to measured. Rated capacity is a laboratory condition. Tested capacity is what the pack does now, after hundreds of cycles and a hot summer.
- Mixing units mid calculation. mAh and Ah, Wh and kWh. Convert everything to one unit before you divide, or you can be out by a factor of a thousand without noticing.
- Missing that energy scales with both Ah and voltage. Doubling the Ah at the same voltage doubles the energy, and so does doubling the voltage at the same Ah. They are two different upgrades with different effects on weight, cost and charging hardware.
Questions fréquemment posées
Multiply amp hours by voltage. A 100Ah battery at 12V holds 1,200Wh. If you only have current rather than charge, multiply voltage by current by hours instead.
No. Amp hours are charge and watt hours are energy, and voltage connects them. A 100Ah battery at 12V holds 1,200Wh. At 48V the same 100Ah holds 4,800Wh.
About 1,280Wh at the 12.8V nominal voltage of lithium iron phosphate, or 1,200Wh if you use the 12V shorthand. The difference is 80Wh, and it grows with bank size.
Depth of discharge, inverter efficiency, temperature and discharge rate all take a share. In the example above, a pack with a 2,560Wh label delivers around 2,100Wh to the load.
Divide by 1,000. 2,560Wh is 2.56kWh. Utilities bill in kWh, so this is the conversion you need to compare a battery against grid cost.
Work Out Your Own Numbers
If you would rather not run the arithmetic by hand, the amp hours to watt hours converter takes voltage and capacity and returns energy.
TYCORUN builds lithium packs from 12V through 48V and above for storage, traction and swap applications, with OEM and ODM customization available on cell, BMS and enclosure. If you have a duty cycle rather than a spec sheet, send it over and we will size the pack against it.

Le nettoyage régulier des panneaux solaires est un élément important pour assurer une production d'énergie continue et efficace, prolonger leur durée de vie et garantir le retour sur investissement.

Qu'est-ce qu'une batterie sans entretien ? Comme expliqué précédemment, une batterie sans entretien est un type de batterie conçu intentionnellement pour ne pas nécessiter d'entretien de routine tel que le remplissage du liquide électrolytique.

Cet article aborde les différences entre l'AGM et l'acide au plomb, de la compréhension à l'application, en passant par les avantages et les inconvénients de l'AGM par rapport à l'acide au plomb.
Auteurs
-
Voir tous les messages
Ryder est un spécialiste des batteries au lithium et un auteur de contenu technique qui possède plus de cinq ans d'expérience approfondie dans le domaine de l'infrastructure de la mobilité électrique. Il est spécialisé dans les tests de cellules, les diagnostics de packs et l'analyse des performances du système de gestion de la batterie (BMS) dans le monde réel. Ayant collaboré étroitement avec des équipes de R&D de premier plan, Ryder excelle dans l'évaluation de la sécurité des batteries par rapport à des normes mondiales rigoureuses telles que UN38.3 et IEC 62133. Dans ses articles, il s'efforce d'éliminer le bruit du marketing et d'offrir aux lecteurs des informations brutes et fondées sur des données concernant la sécurité, les performances et l'optimisation de la durée de vie des batteries.
-
Voir tous les messages
Meg est ingénieur en batteries et possède plus de 10 ans d'expérience dans le secteur du stockage de l'énergie. Elle est titulaire d'une licence en génie électrique et a travaillé auparavant comme ingénieur R&D chez un fabricant de batteries lithium-ion, où elle s'est concentrée sur les systèmes de gestion des batteries (BMS), les algorithmes de charge et les tests de cycle de vie pour les batteries plomb-acide, AGM et lithium. Elle a contribué au développement des technologies de maintenance des batteries utilisées dans les produits commerciaux. Meg assure aujourd'hui la révision technique du contenu relatif au stockage de l'énergie afin de garantir l'exactitude, la sécurité et la valeur pratique pour les lecteurs.