Battery Degradation: Causes, Effects, and Mitigation Strategies

This article delves into the phenomena of battery degradation, its mechanisms, influencing factors, monitoring methods, as well as strategies to mitigate degradation and future development trends.

Author :

Reviewers:

Last Updated on February 19, 2025

Batteries, as essential energy storage devices in modern society, are widely used in consumer electronics, energy storage systems, and electric vehicles. However, during prolonged use, batteries experience capacity degradation, leading to a decrease in their energy storage capability. This article delves into the phenomena of battery degradation, its mechanisms, influencing factors, monitoring methods, as well as strategies to mitigate degradation and future development trends.

Table of Contents
    Add a header to begin generating the table of contents
    YouTube_play_button_icon

    What Does Battery Degradation Mean?

    Battery degradation refers to the gradual decrease in capacity and efficiency of a battery during use. Over time, the chemical reactions inside the battery reduce its ability to store electrical energy, thereby affecting the endurance of devices.

    What Are the Signs of Battery Degradation?

    In practical applications, battery degradation mainly manifests in the following ways:

    Decrease in Battery Capacity

    Battery capacity refers to the amount of electrical energy a battery can store, typically measured in amp-hours (Ah) or kilowatt-hours (kWh). As usage time increases and the number of charge and discharge cycles rises, chemical reactions within the battery can lead to structural changes in the electrode materials and a reduction in active material, gradually diminishing the amount of charge the battery can store. For example, a new battery may have a capacity of 60 kWh, but over several years, it could drop to 50 kWh or lower.

    Shortened Endurance

    For battery-powered products such as portable devices and electric tools, the effective endurance time diminishes due to the decrease in capacity. This change can directly affect the user experience, necessitating more frequent recharging.

    Prolonged Charging Time

    Degradation of the battery can also lead to longer charging times. As the battery ages, internal resistance increases, resulting in greater energy loss during charging, ultimately requiring more time to fully charge.

    Reduced Charging Efficiency

    A degraded battery will charge less energy than what is input. This not only affects the charging efficiency but also leads to energy wastage, making the heating during the charging process more pronounced.

    The Principle Of Battery Degradation

    The mechanisms of battery degradation involve various physical and chemical processes, including the following:

    Structural Changes in Electrode Materials

    • Lithium-ion Batteries (such as NMC and LFP): During charge and discharge cycles, lithium ions embed and extract between the positive and negative electrodes. As the number of cycles increases, the crystal structure of the electrode materials gradually degrades. For instance, in a NMC battery, frequent lithium ion extraction can alter the layered structure of the positive electrode material, leading to lattice defects that hinder further lithium embedding and extraction, thus reducing battery capacity.
    • Lithium Metal Batteries: When lithium metal serves as the negative electrode, it continuously deposits and dissolves during charge and discharge. This process may lead to the formation of lithium dendrites, which consume lithium metal and could pierce the separator, causing short circuits and irreversible losses in battery capacity.

    Loss of Active Material

    • Dissolution and Shedding

    Some active materials in the electrode may dissolve into the electrolyte. For example, transition metal ions (such as cobalt ions) from some positive electrode materials can dissolve into the electrolyte over prolonged electrochemical processes, reducing active material content. Additionally, during charge and discharge, the electrode materials may experience shedding due to volume changes, particularly evident during high-rate charge and discharge, with active materials detaching from the electrodes and no longer participating in electrochemical reactions, leading to capacity decline.

    • Consumption from Side Reactions

    Various side reactions occur within the battery. For instance, the electrolyte may oxidize and decompose at high voltages, producing gases and consuming active materials. These side reactions not only reduce the effective active material but may also alter the chemical environment within the battery, impacting performance.

    Increase in Internal Resistance

    • Thickening of the Solid Electrolyte Interface (SEI) Film

    During initial charging, the electrolyte decomposes on the surface of the negative electrode, forming a SEI film. Over subsequent charge and discharge cycles, this film continues to grow and change. As usage time increases, the SEI film thickens, with high resistance hindering lithium ion transport and increasing internal resistance.

    • Decline in Conductivity of Electrode Materials

    The conductivity of electrode materials significantly impacts battery performance. Over time, conductive additives within electrode materials may agglomerate or have decreased contact with active materials, leading to reduced conductivity and increased internal resistance. This results in more heat generation during charge and discharge, further accelerating degradation.

    Classification of Battery Degradation

    Can battery degradation be reversed? The battery degradation can be categorized into two types: reversible degradation and irreversible degradation. The distinction lies in whether the degradation can be restored through appropriate measures.

    Reversible Degradation

    Reversible degradation refers to temporary performance declines occurring during battery use, which can be partially or completely restored through appropriate measures. Common phenomena include:

    • Polarization: During rapid charging or high-rate discharging, the concentration and potential of lithium ions at the electrode surface may change, preventing lithium ions from being embedded in the anode, creating concentration polarization. After a period of rest, the lithium ion concentration can rebalance, allowing the battery’s performance to recover.
    • Low-Temperature Effects: In low-temperature environments, the viscosity of the electrolyte increases, slowing down the diffusion rate of lithium ions, resulting in reduced capacity and charge/discharge performance. However, when the battery returns to a suitable temperature, its performance can recover. For instance, the range of electric vehicles decreases in winter due to lower temperatures, but in warmer conditions, the battery’s performance and range return to normal once it warms up.

    Irreversible Degradation

    Irreversible degradation is characterized by permanent structural changes occurring within the battery, leading to capacity that cannot be restored. Common irreversible degradation phenomena include:

    • Electrode Material Structural Damage

    With repeated charge and discharge cycles, the lattice of electrode materials can deform, hindering the effective transport of lithium ions. For example, the nickel-cobalt-manganese (NCM) cathode in ternary lithium batteries is prone to lattice defects with prolonged use, causing irreversible capacity loss.

    • Loss of Active Material:
    1. Dissolution Loss: Transition metal ions (such as cobalt ions) in the cathode material may dissolve into the electrolyte, reducing the available active material and leading to capacity decline.
    2. Detachment Loss: During charge and discharge cycles, the electrode material can experience changes due to volume expansion and contraction. For instance, silicon-based anode materials, which undergo significant volume changes, may easily detach. The detached active material can no longer participate in electrochemical reactions, resulting in permanent capacity loss.

    Factors Influencing Battery Degradation

    Battery degradation is influenced by multiple factors, primarily including:

    Battery Cycle Count

    The cycle count is one of the most direct factors affecting capacity degradation. Each charge-discharge cycle leads to electrode side reactions, active material consumption, and increased electrode impedance, gradually reducing battery capacity. Initial degradation occurs rapidly, then stabilizes, but with increased cycle counts, degradation accelerates and ultimately affects battery lifespan.

    Temperature

    High temperatures can accelerate chemical reactions, hastening SEI film growth, increasing active material loss, and exacerbating electrolyte decomposition, leading to faster battery aging. Low temperatures slow the diffusion rate of lithium ions and decrease electrochemical activity, thereby increasing internal resistance and reducing usable capacity; prolonged low-temperature usage may cause irreversible damage.

    Charge and Discharge Rates

    High-rate charge and discharge can exacerbate polarization phenomena, increasing mechanical and chemical stress, leading to decreased SEI film stability, structural damage to electrode materials, and shedding of active materials, accelerating capacity degradation. Low-rate charge and discharge can mitigate these adverse effects, prolonging battery life and maintaining capacity performance.

    Usage Habits

    Improper charging and discharging practices, such as overcharging and deep discharging, can harm the battery and shorten its lifespan.

    How to Assess Battery Degradation Degree

    Effective monitoring of battery status is crucial for maintenance and extending lifespan. The main monitoring methods include:

    1. Voltage Monitoring:Real-time monitoring of battery voltage and open-circuit voltage (OCV) is conducted through a Battery Management System (BMS), (explore more about can you put a external BMS on a lithium battery?). Battery degradation alters the relationship between OCV and state of charge (SOC). Regularly measuring OCV and comparing it with the initial state can help assess the degree of degradation.
    2. Current Monitoring:The BMS records charge and discharge currents. As batteries degrade, internal resistance increases, leading to reduced charging currents and affected discharge current output. Long-term monitoring of current changes can assist in evaluating battery degradation.
    3. Temperature Monitoring:Temperature is a key factor affecting battery performance. The BMS monitors the operational temperature of the battery, as degradation may cause abnormal heat generation during charge and discharge processes. Abnormal changes in temperature can indirectly indicate whether the battery is degrading.
    4. Internal Resistance Monitoring:Internal resistance is an important indicator of battery health, increasing with use. The BMS measures battery internal resistance using AC or DC resistance methods. A significant increase (e.g., exceeding 1.5 times the initial resistance) indicates that the battery has degraded.
    5. SOC and SOH Estimation:The BMS estimates SOC and state of health (SOH) based on the battery’s usage history and current parameters. SOH directly reflects battery degradation; when SOH falls below 80%, the battery is generally considered to be severely degraded.
    6. Charge and Discharge Curve Analysis:The BMS records the voltage-charge (V-Q) and current-time (I-T) curves of the battery. After degradation, changes in the shape of the curves, such as shortened charging platforms and alterations in slope, can accurately assess the degree of battery degradation.

    Through these monitoring methods, it is possible to effectively determine the extent of battery degradation, providing a basis for maintenance and replacement decisions.

    How to Slow down Battery Degradation

    To mitigate the degradation process, the following measures can be taken:

    Optimize Charging Habits

    • Avoid overcharging and deep discharging: Aim to maintain the battery charge between 20%-80%.
    • Control charging speed: Reduce excessively high charging rates and use slow charging to lessen stress on the battery.

    Optimize Usage Environment

    Avoid charging in extreme temperatures: Charging in high-temperature environments exacerbates internal chemical reactions, risking gas generation and battery swelling (explore the lithium-ion battery bulging); low temperatures reduce battery activity, decreasing charging efficiency, and can damage the battery. Strive to use within suitable temperature ranges.

    Regular Maintenance

    Check battery status: Periodically have professionals assess battery health.

    Proper Storage

    Maintain adequate charge when not in use for extended periods: Charge the battery to around 50%-70% to prevent over-discharge, and store it in a cool environment.

    Future Development Trends in Battery Degradation

    With technological advances, new battery technologies are gradually being developed to address degradation challenges.

    • Material Innovation
      Development of new electrode materials and solid-state batteries may help reduce battery degradation and enhance performance.
    • Optimization of Battery Management Systems
      Advanced battery management systems can more accurately monitor and adjust charging and discharging strategies, prolonging battery lifespan.
    • Improvement of Manufacturing Processes
      Higher precision manufacturing can reduce internal defects and lower degradation rates.
    • Battery Recycling and Reuse
      As the electric vehicle market grows, establishing battery recycling systems can effectively recover and reuse retired batteries, minimizing environmental impact.

    Conclusion

    Battery degradation is a complex and multifaceted issue that directly affects battery performance and lifespan. By deeply researching degradation mechanisms, optimizing usage and maintenance strategies, and driving technological progress, we hope to achieve more efficient and durable battery systems in the future, ensuring energy needs across various sectors.

     

    Read more:

    what does mah mean

    top 10 lithium-ion battery manufacturers in South America

    Frequently Asked Questions

    The deterioration time of a battery varies depending on the type and usage; typically, lithium-ion batteries show significant deterioration after 300 to 500 charge-discharge cycles.

    If your device's battery life drastically decreases, charging takes unusually long, or the device frequently shuts down unexpectedly during use, it may be time to replace the battery.

    Lithium-ion batteries typically have a longer lifespan, while nickel-metal hydride and lead-acid batteries have relatively shorter lifespans, generally ranging from 2 to 5 years.

    Old batteries need to be recycled to avoid environmental pollution from improper disposal (getting details about how do I dispose of lithium batteries​?). You can go to designated recycling points or stores for help.

    Yes, the deterioration of a battery's performance directly impacts the device's battery life and stability, potentially leading to unexpected shutdowns or failure to power on.

    YouTube_play_button_icon

    Who We Are

    With over 17 years of experience, TYCORUN is a leading lithium battery manufacturer committed to driving innovation and development of battery technology, and the company’s current business covers two-wheeled and three-wheeled, four-wheeled power batteries, energy storage batteries, inverters, battery swap cabinets and motorcycles. Its products are widely used in Europe, the Middle East, and Africa.

    The company provides customized battery services, from cells to complete systems, and holds certifications like ISO9001, CE, TUV, and UL. TYCORUN has developed solid-state low-temperature batteries for better performance in cold conditions and uses advanced BMS algorithms for safety and longer life. It also prioritizes sustainability with low-pollution materials and eco-friendly production.

    Authors

    • Ryder

      Ryder is a hands-on lithium battery specialist and technical content author with over five years of deep field experience in electric mobility infrastructure. He specializes in cell testing, pack diagnostics, and real-world Battery Management System (BMS) performance analysis. Having collaborated closely with top-tier R&D teams, Ryder excels at evaluating battery safety against stringent global standards like UN38.3 and IEC 62133. Through his articles, he aims to eliminate marketing noise, offering readers raw, data-driven insights into battery safety, performance, and lifespan optimization.

      View all posts
    • Meg

      Meg is a battery engineer with 10+ years of experience in the energy storage industry. She holds a B.S. in Electrical Engineering and previously worked as an R&D engineer at a lithium-ion battery manufacturer, where she focused on battery management systems (BMS), charging algorithms, and life-cycle testing for lead-acid, AGM, and lithium chemistries. She has contributed to the development of battery maintenance technologies used in commercial products. Meg now provides technical review for energy storage content to ensure accuracy, safety, and practical value for readers.

      View all posts
    Table of Contents
      Add a header to begin generating the table of contents

      You Might Also Like...

      How to Convert Amp Hours to Watt Hours (Ah to Wh Calculator and Chart)

      How to Convert Amp Hours to Watt Hours (Ah to Wh Calculator and Chart)

      Convert amp hours to watt hours with one formula: Wh = Ah × V. This guide gives you a calculator, lookup charts from 12V to ...
      Lithium Battery for RV Off-Grid Sizing and Cold Charging

      Lithium Battery for RV: Off-Grid Sizing and Cold Charging

      Planning an off-grid RV trip or camping in winter? Find out how much battery capacity you need, how to match it to your appliances, and ...
      Ganfeng Begins 588Ah Storage Cell Ramp; 648Ah Planned for 2027

      Ganfeng Ramps 588Ah Storage Cells, 648Ah Due 2027

      Ganfeng LiEnergy has moved its 588Ah storage cell line into production ramp and scheduled a 648Ah cell for 2027. This article converts the new formats ...
      EU Battery Passport 2027 Requirements for LMT and Energy Storage Batteries

      EU Battery Passport 2027: Requirements for LMT and Energy Storage Batteries

      From 18 February 2027, LMT batteries, EV batteries and industrial batteries above 2 kWh need an EU battery passport. See what the record contains, who ...
      EU Battery Regulation 20231542 What Battery Buyers Need to Know

      EU Battery Regulation 2023/1542: What Battery Buyers Need to Know

      A buyer’s breakdown of Regulation (EU) 2023/1542 for e-mobility and stationary storage. Learn how LMT and industrial batteries are classified, what applies from CE marking ...
      Lithium Battery vs Lithium-Ion Battery What’s the Real Difference

      Lithium Battery vs Lithium-Ion Battery: What’s the Real Difference?

      Lithium vs lithium-ion mostly comes down to single-use versus rechargeable. Here is how to read the label, compare voltage and shelf life, and pick the ...